As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NDIS 660 33-50 0039670 20FEB22 SBY CLOSE SERVICE DOOR EMERGENCY LIGHT IS INOP.
FACT 20FEB22 09:45 SBY R&R'D LAMP. NO FIX. LIGHT LEASE COVER IS REMOVED. REPAIRED BROKEN WIRE TO SERVICE DOOR EMERGENCY LIGHT AT SERVICE DOOR HINGE ATTACH POINT WITH AN ENVIRON-MENTAL SPLICE I.A.W. S.W.P.M. 20-21-00. OPS CHECK GOOD AND REINSTALLED ORIGINAL LIGHT LENSE COVER.