What was found
BLEED ENGINE LEAK 2 IN CLIMBING THROUGH 10000 FT RAN QRH AND EXTINGUISHED. FOUND BLEED PIPE FWD OF #2 ENGINE PRSOV DAMAGED/LEAKING. R+R BLEED PIPE REF 36-11-09. OK FOR SERVICE LEAK CHECK GOOD
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BLEED ENGINE LEAK 2 IN CLIMBING THROUGH 10000 FT RAN QRH AND EXTINGUISHED. FOUND BLEED PIPE FWD OF #2 ENGINE PRSOV DAMAGED/LEAKING. R+R BLEED PIPE REF 36-11-09. OK FOR SERVICE LEAK CHECK GOOD