Service difficulty report · Actuator · Emb EMB145LR

Difficulty date
December 5, 2022
Submitted
December 7, 2022
Operation
Air carrier
Aircraft
N672AE
Make and model
Emb EMB145LR
Aircraft serial
145794
Part
Actuator
Condition
Damaged
Location
Gust Lock Switch
Stage of operation
TO
How discovered
O
Nature of condition
O
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

GUST LOCK WOULD NOT UNLOCK ON RUNWAY. PERFORMED ELECTRICAL RESET, FOUND GUST LOCK TO OPERATE NORMALLY. PERFORMED GUST LOCK OPS CHECK IAW AMM 27-70-00. OPS CHECK SATISFACTORY, ACFT OK FOR SERVICE. ACCESSED SOLENOID UNDER GUST LOCK LEVER MANUALLY DEPRESSED SOLENOID AND MOVED GUST LOCK LEVER TO FULL UNLOCKED POSITION. ELEVATOR GUST LOCK STILL ENGAUGED. INSPECTED CONTROL COLUMN POSITION SWITCH. FOUND FLAT SPOT ON SWITCH ACTUATOR ROLLER. R & R ACTUATOR IAW AMM 27-71-11. PERFORMED GUST LOCK OPS CHECK IAW 27-71-00-700-801-A, OPS CHECKED GOOD.