What was found
E975872 SSI 53-30-48, CARGO DOOR LOWER SILL FWD EDGE HAS LEVEL 2 CORROSION. : BLENDED CORROSION ON CARGO DOOR LOWER SILL FWD EDGE IAW EMB 145 SRM 51-10-03. HASN’T BEEN PREVIOUSLY BLENDED. REMAINING THICKNESS AT BLENDED AREAS ON CARGO DOOR LOWER SILL FWD EDGE FOUND TO BE BEYOND LIMITS IAW EMB145 SRM 53-31-15AD, ITEM 2. REMOVED CARGO DOOR LOWER SILL IAW EMB-145 SRM 51-40-02.INSTALLED SERVICEABLE CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02