What was found
3FLOOR STRIP EMERGENCY LIGHTS FROM LAV DOOR TO SEAT #12 ARE INOP. R & R INVERTER # 6 IAW AMM 33-50-11 OP TEST GOOD
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
3FLOOR STRIP EMERGENCY LIGHTS FROM LAV DOOR TO SEAT #12 ARE INOP. R & R INVERTER # 6 IAW AMM 33-50-11 OP TEST GOOD