What was found
00233 AFTER REMOVAL OF CENTER Y0 FLOOR SUPPORT CAP FOUND ATTACHING BEAM IS CORRODED BETWEEN FRM59 AND FRM60. COMPLIED WITH EMB145 ETD 2024-145-004237 REV A PERMANENT REPAIR PROCEDURE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
00233 AFTER REMOVAL OF CENTER Y0 FLOOR SUPPORT CAP FOUND ATTACHING BEAM IS CORRODED BETWEEN FRM59 AND FRM60. COMPLIED WITH EMB145 ETD 2024-145-004237 REV A PERMANENT REPAIR PROCEDURE