E2 ANTI ICE FAIL. CW MX PROCEDURE. MEL 25MAY24 10:25 PHL C14602 30-8-1 ENGINE ANTI-ICE. FACT 28MAY24 02:00 PHL T/S IRW FIM 30-21-00-810-804-A, FOUND CONNECTOR P0973 WOULD NOT SEAT, HAD DAMAGED SHIELDING. R&R CONNECTOR IRW SWPM 20-50-00. RAN E2 AND PERFORMED OPS CHECK. OPS CHECK GOOD, OK FOR SERVICE. CLEAR MEL 30-8-1