What was found
E1 BLD VLV FAIL MSG ON EICAS. FACT 22JAN25 00:03 PHL R+R BLEED VALVE IAW AMM 36-11-05. BLEED 1 LEAK ON EICASE DURING OPS CHK. FOUND Y DUCT AT #1 DUAL TEMP VLV LEAKING. R+R COUPLING IRW AMM 21-60-01. OPS CHK GOOD
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E1 BLD VLV FAIL MSG ON EICAS. FACT 22JAN25 00:03 PHL R+R BLEED VALVE IAW AMM 36-11-05. BLEED 1 LEAK ON EICASE DURING OPS CHK. FOUND Y DUCT AT #1 DUAL TEMP VLV LEAKING. R+R COUPLING IRW AMM 21-60-01. OPS CHK GOOD