What was found
F034870 CENTER FLOOR BEAM GUSSET HAS MULTIPLE SPOT OF CORROSION BETWEEN FR39 AND FR43. RAR CENTER FLOOR BEAM GUSSET BETWEEN FR39 AND FR43 IAW EMB 145 SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
F034870 CENTER FLOOR BEAM GUSSET HAS MULTIPLE SPOT OF CORROSION BETWEEN FR39 AND FR43. RAR CENTER FLOOR BEAM GUSSET BETWEEN FR39 AND FR43 IAW EMB 145 SRM 51-40-02.