What was found
GALLEY FLOOR CROSSBEAM AT FR18 BETWEEN LH FLOOR SILL #1 AND LH OMEGA BEAM HAS CORROSION. R&R GALLEY FLOOR CROSSBEAM AT FR18 BETWEEN LH FLOOR SILL #1 AND LH OMEGA BEAM IAW EMB 145 SRM51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GALLEY FLOOR CROSSBEAM AT FR18 BETWEEN LH FLOOR SILL #1 AND LH OMEGA BEAM HAS CORROSION. R&R GALLEY FLOOR CROSSBEAM AT FR18 BETWEEN LH FLOOR SILL #1 AND LH OMEGA BEAM IAW EMB 145 SRM51-40-02.