What was found
BLEED 2 VLV FAIL CAUTION MSG ON ATTEMPTED T/O AROUND 32 KTS. ENG BLEED SYSTEM R&R ENGINE 2 BLEED VALVE IRT AMM 36-11-05.OPS CHECK GOOD.OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BLEED 2 VLV FAIL CAUTION MSG ON ATTEMPTED T/O AROUND 32 KTS. ENG BLEED SYSTEM R&R ENGINE 2 BLEED VALVE IRT AMM 36-11-05.OPS CHECK GOOD.OK FOR SERVICE.