STRINGER 3L AT FR20 IS CRACKED. REMOVED AND REPLACED MACHINED STGR 3L BTW FR 19-20 IAW EMB 145 SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 3L AT FR20 IS CRACKED. REMOVED AND REPLACED MACHINED STGR 3L BTW FR 19-20 IAW EMB 145 SRM 51-40-02.