What was found
LEFT OMEGA BEAM CENTER FLOORBOARD SUPPORT AND RH SIDE OF BEAM HAS CORROSION BETWEEN FRAMES 24-27. BLENDED OUT CORROSION ON LH OMEGA BEAM CENTER FLOORBOARD SUPPORT AND RH SIDE OF BEAM BETWEEN FRAMES 24-27 IAW EMB 145 SRM 51-10-03. REMAINING THICKNESS AT BLENDED AREAS FOUND TO BE WITHIN ALLOWABLE LIMITS IAW EMB 145 SRM 53-22-10-AD. REPAIRED THE CRACKED AREA LOCATED AT LH OMEGA BEAM AT FR 26 SUPPORT IAW EMB ETD2025-145-931696 REV A AND EO1-53-25-0414.