What was found
FRAME DOUBLER CORRODED AT FR 61 LT. PERFORMED CUTOUT, FABRICATED & REINSTALLED REPAIR DOUBLER IAW SRM 53-31-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME DOUBLER CORRODED AT FR 61 LT. PERFORMED CUTOUT, FABRICATED & REINSTALLED REPAIR DOUBLER IAW SRM 53-31-04.