What was found
MID FLOOR GUSSET FROM FR 31 TO FR 35 HAS CORROSION. INSTALLED NEW MID FLOOR GUSSET FROM FR29.5 TO FR 35.5 REF EMB 145 SRM 51-40-02, SRM 51-20-0
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID FLOOR GUSSET FROM FR 31 TO FR 35 HAS CORROSION. INSTALLED NEW MID FLOOR GUSSET FROM FR29.5 TO FR 35.5 REF EMB 145 SRM 51-40-02, SRM 51-20-0