What was found
AFTER REMOVAL OF LH FLOOR SILL AT FR 23 TO FR 29 FOUND ELONGATED HOLE AT FR 24. COMPLIED WITH PERMANENT REPAIR ON FR 24 BETWEEN STR 15L - 16L PER EMB145 SRM 53-00-04 ITEM 14 FIGURE 206, ETD2026-145-002730 REV.:/, AND EO1-53-26-0088
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER REMOVAL OF LH FLOOR SILL AT FR 23 TO FR 29 FOUND ELONGATED HOLE AT FR 24. COMPLIED WITH PERMANENT REPAIR ON FR 24 BETWEEN STR 15L - 16L PER EMB145 SRM 53-00-04 ITEM 14 FIGURE 206, ETD2026-145-002730 REV.:/, AND EO1-53-26-0088