Service difficulty report · Wire · Emb EMB145LR

Difficulty date
April 7, 2026
Submitted
April 8, 2026
Operation
Air carrier
Aircraft
N922AE
Make and model
Emb EMB145LR
Aircraft serial
14500906
Aircraft time
46,814 hours, 42,767 cycles
Part
Wire
Condition
Failed Insp
Location
Zone 100
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BATTERY 1 OVERTEMP IN FLIGHT, 74C. T/S PER FIM TASK 24-36-00-810-805-A. WIRE W002-0001-20WH FOR PIN B ON CONNECTOR P1007 FAILED ELECTRICAL CHECK. REPAIRED DAMAGE USING SWPM 20-21-00, EICAS INDICATION CORRECT TEMP FROM SENSOR AND THERMOMETER READINGS AT 21 DEGREES C. OPS CK GOOD.