What was found
MID OMEGA BEAM FLANGE FROM FR 23 TO FR 29 HAS CORROSION. BLENDED 6 QTY AREAS ON MID OMEGA BEAM FLANGE FROM FR 24 TO 29 TO REMOVE CORROSION. ALL 6 AREAS FOUND TO BE IN LIMITS IAW EMB 145 SRM 53-22-10-AD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID OMEGA BEAM FLANGE FROM FR 23 TO FR 29 HAS CORROSION. BLENDED 6 QTY AREAS ON MID OMEGA BEAM FLANGE FROM FR 24 TO 29 TO REMOVE CORROSION. ALL 6 AREAS FOUND TO BE IN LIMITS IAW EMB 145 SRM 53-22-10-AD.