Service difficulty report · Sensor · Emb EMB145LR

Difficulty date
July 18, 2026
Submitted
July 20, 2026
Operation
Air carrier
Aircraft
N646AE
Make and model
Emb EMB145LR
Aircraft serial
145213
Aircraft time
53,779 hours, 51,111 cycles
Part
Sensor
Condition
Failed
Location
Zone 400
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED NR 2 OVERTEMP MESSAGE DISPLAYED, FOLLOWED QRH MESSAGE CLEARED. REF 36-11-00-810-1 CMC MSG DUCT SENSOR FAIL W/ NO OTHER RELATED MESSAGES. R & R BLEED 2 OUTLET TEMP SENSOR IAW AMM 36-20-01 PERFORMED IDLE RUN IRT RUN UP CHECKLIST NO ABNORMAL TEMP READING NOTED FOR 15MIN AC OK FOR SERVICE AT THIS TIME.