As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB RUDDER SYSTEM 1-2 INOPERATIVE MESSAGE ON EICAS. R & R PRESSURE SWITCH IAW AMM 27-23-04-000/400-801-A. FOUND SYS 1 SOLENOID IN PCU MAKING BUZZING SOUND WHILE HYD SYS 1 ENGAGED. R & R PCU IAW AMM 27-22-03-000/400-801-A. OPS CHECKED GOOD. LEAK CHECKED GOOD. OK FOR SERVICE.