As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TWO FLOOR EMERGENCY LIGHT STRIPS INOPERATIVE, NR 4 AND 5. WIRING REPAIRS WERE PERFORMED BY DESOLDERING AND RESOLDERING THE AFFECTED CONNECTIONS, LIGHTS #4 AND #5 WERE THEN REINSTALLED IN ACCORDANCE WITH EMB 145 SWPM 20-30-00. & AMM 33-50-11-400-801-A