What was found
DURING 4800/9600 HOUR STRUCTURAL INSP, THE FOLLOWING ITEMS WERE FOUND. CORROSION DAMAGE ON FUSELAGE SKIN FOUND AT STA 213.2-FUEL TANK RT OF CENTERLINE. REMOVED CORROSION, TREATED AREA AND INSTALLED DOUBLER FABRICATED FROM 2024 T3 .032 - 6" X 9" IN SIZE AT STA 213.2- (7) INCHES RT OF CENTERLINE IAW SRM 53-00-00. CORROSION DAMAGE FOUND AT STA 187.2-FUEL TANK RT OF CENTERLINE. REMOVED CORROSION, TREATED AREA AND INSTALLED DOUBLER FABRICATED FROM 2024 T3 .032 -7" X 6" IN SIZE AT STA 187.2 - (7) INCHES RT OF CENTERLINE IAW SRM 53-00-00.