What was found
DURING 4800/9600 HOUR STRUCTURAL INSP THE FOLLOWING ITEMS WERE FOUND. RT FWD TENSION STRAP AT STA 238.17 HAS CORROSION DAMAGE. REMOVED CORROSION,TREATED AREA AND INSTALLED DOUBLER FABRICATED FROM 2024 T351 .190- SIZE (26" X 4"). REPAIRED IAW ENGINEERING REPORT NR 8434-2 REV IR. LT AFT TENSION STRAP AT STA 264.77 HAS CORROSION DAMAGE. REMOVED CORROSION, TREATED AREA AND INSTALLED DOUBLER FABRICATED FROM 2024 T351 .190-SIZE (29" X 5"). REPAIRED IAW ENGINEERING REPORT NR 8434-2 REV. IR.