What was found
DURING SCHEDULED PHASE INSPECTION, MX FOUND EXFOLIATION CORROSION ON CENTER SEAT TRACK BETWEEN FUSELAGE BS 329.5 AND 332. CORROSION MEASURES 2.5" IN LENGTH AND .5" IN WIDTH - WITH A MAXIMUM DEPTH PENETRATION MEASUREMENT OF 4/32". OPEN
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED PHASE INSPECTION, MX FOUND EXFOLIATION CORROSION ON CENTER SEAT TRACK BETWEEN FUSELAGE BS 329.5 AND 332. CORROSION MEASURES 2.5" IN LENGTH AND .5" IN WIDTH - WITH A MAXIMUM DEPTH PENETRATION MEASUREMENT OF 4/32". OPEN