Service difficulty report · Circuit Breaker · Cessna 402C

Difficulty date
August 23, 2004
Submitted
February 23, 2005
Operation
Air carrier
Aircraft
N2615G
Make and model
Cessna 402C
Aircraft serial
402C0101
Engine
Cont TSIO520VB
Part
Circuit Breaker
Part number
W31K2M1G75
Condition
Failed
Location
Lt Cb Panel
Component
Anti Coll Light · Grimes
Component part number
31317211
Stage of operation
LD
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON SHORT FINAL, CREW REPORTED SMELL OF SMOKE, TO REDUCE LOAD ALL LIGHTS WERE TURNED OFF, SMELL DISSIPATED. MECHANIC FOUND ANTI COLLISION WIRING DAMAGED NEAR C/B PANEL AND CIRCUIT BREAKER FAILED. REPAIRED WIRING, REPLACED BREAKER AND RETURNED AIRCRAFT TO SERVICE. (NE01200406991) (K)