What was found
FOUND FLOORBEAM AT FRAME 13 IS CORRODED. CORROSION REMOVED AND FOUND TO BE BEYOND MANUFACTURERS LIMITS. REPAIRED FLOORBEAM WITH SPLICE IN ACCORDANCE WITH SRM 53-00-00 FIGURE 435.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM AT FRAME 13 IS CORRODED. CORROSION REMOVED AND FOUND TO BE BEYOND MANUFACTURERS LIMITS. REPAIRED FLOORBEAM WITH SPLICE IN ACCORDANCE WITH SRM 53-00-00 FIGURE 435.