What was found
PILOT REPORTED FUEL SMELL IN CABIN WITH HEATER RUNNING. INSPECTED & FOUND HEATER FUEL SCREEN BOWL IN RT WING HOSE & LEAKING. RE-TIGHTENED SCREEN BOWL IAW MM CH 21-40-00. OPERATIONS & LEAK CHECKED GOOD AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PILOT REPORTED FUEL SMELL IN CABIN WITH HEATER RUNNING. INSPECTED & FOUND HEATER FUEL SCREEN BOWL IN RT WING HOSE & LEAKING. RE-TIGHTENED SCREEN BOWL IAW MM CH 21-40-00. OPERATIONS & LEAK CHECKED GOOD AT THIS TIME.