What was found
WHILE PERFORMING THE SID 57-10-25 INSPECTION, THREE CRACKS WHERE IDENTIFIED IN THE RIGHT CLOSE-OUT RIB (P/N 5122155-56.) THESE CRACKS WERE FOUND ON THE FORWARD ROW OF AT THE REAR TRUNNION PLATE ATTACH POINT. THERE ARE 6 HI-LOK HOLES ALIGNED VERTICALLY IN THIS ROW OF FASTENERS. THE FIRST CRACK IS 1.75 INCHES LONG AND WAS FOUND ON THE THIRD HOLE FROM THE TOP IN THIS ROW. CRACK TWO IS 1.5 INCHES LONG AND WAS FOUND AT THE FOURTH HOLE IN THIS ROW. CRACK THREE IS .75 INCHES LONG AND WAS FOUND AT THE FIFTH HOLE IN THIS ROW. THESE CRACKS ARE SIMILAR IN FASHION TO PREVIOUS SDR SUBMISSIONS.