What was found
DURING SCHEDULED NDT INSPECTION AS NOTED IN SID 57-10-16, A CRACK WAS NOTED ON THE RIGHT HAND OUTBOARD NACELLE FITTING P/N: 5292029-32. THE CRACK MEASURES .125 INCHES LONG AND IS CONSISTENT WITH OTHERS FOUND USING THE LIGHTED BORESCOPE INSPECTION TECHNIQUE (TEXTRON MEL54-02R3). THE LAST LIGHTED BORESCOPE INSPECTION TO SATISFY AD 2017-10-09 WAS PERFORMED AT ACTT: 32277.8 AND 19210 CYCLES. THE LAST NDT INSPECTION AS NOTED IN CESSNA SID 57-10-16 WAS PERFORMED AT ACTT: 32001.0 AND 18801 CYCLES. THIS FITTING WILL BE REPLACED USING NEW PARTS.