What was found
AFT GALLEY EMERGENCY EXIT LIGHT INDICATORS INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY WITH SERVICEABLE UNIT AT STA 920 IAW B737-300 AMM 33-51-51. TEST OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT GALLEY EMERGENCY EXIT LIGHT INDICATORS INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY WITH SERVICEABLE UNIT AT STA 920 IAW B737-300 AMM 33-51-51. TEST OK.