What was found
REFER TO LOGPAGE 42606 ITEM 2. LEFT ENG BLEED OFF LIGHT. PERFORMED PNEUMATIC HEALTH CHECK REF AMM 36-00-22, FOUND PRESSURE REGULATING SHUT-OFF VALVE FAULTY. REMOVED AND REPLACED PRSOV PER AMM 36-11-09. OPERATIONAL CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REFER TO LOGPAGE 42606 ITEM 2. LEFT ENG BLEED OFF LIGHT. PERFORMED PNEUMATIC HEALTH CHECK REF AMM 36-00-22, FOUND PRESSURE REGULATING SHUT-OFF VALVE FAULTY. REMOVED AND REPLACED PRSOV PER AMM 36-11-09. OPERATIONAL CHECK NORMAL.