What was found
DURING HEALTH CHECK, FOUND DISCREPANCY WITH L ENG HS PILOT VALVE PER AMM 36-00-22. REPLACED L ENG HS PILOT VALVE PER AMM 36-11-19. OPS AND LEAK CHK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEALTH CHECK, FOUND DISCREPANCY WITH L ENG HS PILOT VALVE PER AMM 36-00-22. REPLACED L ENG HS PILOT VALVE PER AMM 36-11-19. OPS AND LEAK CHK GOOD.