What was found
FLT. NO: MGE411 ESI - EICAS R PACK TEMP. PERFORMED FIM 21-51 FT 803. FOUND RH MIX MANIFOLD SENSOR FAULT LIGHT. REPLACED SENSOR PER AMM 21-61-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT. NO: MGE411 ESI - EICAS R PACK TEMP. PERFORMED FIM 21-51 FT 803. FOUND RH MIX MANIFOLD SENSOR FAULT LIGHT. REPLACED SENSOR PER AMM 21-61-02.