Service difficulty report · Inverter · Gulstm GIV

Difficulty date
September 9, 2015
Submitted
October 23, 2015
Operation
Air carrier
Aircraft
N2129
Make and model
Gulstm GIV
Aircraft serial
1117
Part
Inverter
Part number
506701
Part serial
SB2161
Condition
Failed
Location
E&E Bay
Part time
6,829 hours
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 INERTIAL REF UNIT RACK FAN INVERTER SUFFERED A CATASTROPHIC FAILURE DURING GND OPERATION WITH GND POWER APPLIED. THE ENCLOSED UNIT APPEARS TO HAVE EJECTED ITS COVER, INTERNAL PARTS & POTTING, INCLUDING A TOROIDAL TRANSFORMER. THERE ARE SIGNS OF HEAT DAMAGE & MELTED VARNISH & POTTING COMPOUND INTERNAL & EXTERNAL ON THE CASE & EJECTED PARTS. THE CREW DID DETECT AN ELEC BURNING ODOR MOMENTARILY, EMITTED FROM THE LT AVIONICS RACK AREA. NO CB POPPED & ONLY FURTHER INDICATION TO THE CREW OF A FAILURE, WAS A LONG DELAYED & INTERMITTENT NR 1 IRU FAN FAIL, CAS MSG AT 1 POINT DURING NR 1 IRU OPERATION. AFFECTS TO THE AREA SURROUNDING & EXTERNAL TO THE UNIT INCLUDE CONTAMINATION FROM EJECTED DEBRIS & MELTED VARNISH. ONLY A THOROUGH CLEANUP OF THE AREA REQUIRED TO CORRECT. REPLACING THE OTHER 2 REMAINING LIKE UNITS THAT ARE INSTALLED IN THE ACFT. THE MFG HAS A NEW & IMPROVED PART TO REPLACE THIS.