What was found
LT CANTED FRAME AT FS 1485 LONGERON 8L TO 13L IS EXFOLIATED AT FASTENER HOLES. REMOVED DAMAGED FRAME, FABRICATED AND INSTALLED NEW FRAME PER SRM 51-10-2 USING 7075-0 .050 HEAT TREATED TO T-6, MATERIAL ID PER DC-9 SRM 53-14-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT CANTED FRAME AT FS 1485 LONGERON 8L TO 13L IS EXFOLIATED AT FASTENER HOLES. REMOVED DAMAGED FRAME, FABRICATED AND INSTALLED NEW FRAME PER SRM 51-10-2 USING 7075-0 .050 HEAT TREATED TO T-6, MATERIAL ID PER DC-9 SRM 53-14-4.