What was found
INSPECTION TYPE:C LEFT O/B FLAP I/B UPPER SKIN PREVIOUS REPAIR HAS A GOUGE REPAIR LOCATE 35.0 INCHES FROM I/B EDGE 25 INCHES FWD OF T/E PER EO B757-5100-30760-B APPEN 'C', CONTACT ON SITE ENGR FOR DISPO. OUT OF LIMIT SRM 57-53-01-1A (2) REMOVED PREV REPAIR SRM 51-70-10/5 /57-53-01, CLEAN PREP AREA SRM 51-70-102R4, FAB DOUBLER ALU 7075-T6 040 APL BOEGEL P/N04-002-0203 BTEN 0001489157 REPAIR SRM 51-70-10 2R4 FIG 2 SH2 APL ADHESIVE PRIMER ON REPAIR P/N 04-009-0008 BTEN 00153214 SRM 51-70-10-2R4 FIG 2 SH 2.