What was found
INSPECTION TYPE:C3 48 SECTION INTERNAL CORROSION AROUND PERIPHERY OF APU INLET HOUSING ASSY AND ATTACHMENT NUT PLATES, BS 1787 TO 1825 STR 3 RT TO STR 6RT. REPAIRED PER 757 SRM 53-00-03-1A, SRM 51-10-02 SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3 48 SECTION INTERNAL CORROSION AROUND PERIPHERY OF APU INLET HOUSING ASSY AND ATTACHMENT NUT PLATES, BS 1787 TO 1825 STR 3 RT TO STR 6RT. REPAIRED PER 757 SRM 53-00-03-1A, SRM 51-10-02 SRM 51-40-02.