INSPECTION TYPE:C2 CORROSION AND TOOLING MARKS ON INTERCOSTAL AT BS 1055 RBL 27-43 WL 208. BLENDED CORROSION AND TOOLING MARKS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED PER SRM 51-40-05 AND OHM 20-50-01.