INSPECTION TYPE:C MAIN EQUIPMENT CENTER BS 246 FLOORBEAM ATTACH CLIP 1EA CRACKED AT LBL 50" ( CRACK 0.875" LENGTH ) FUSELAGE BS 246 LBL 50" MAIN EQUIPMENT CENTER FLOORBEAM ATTACH CLIP REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02.