What was found
INSPECTION TYPE:ETOP ATB - LT ENG PRI AND STBY EGT INOP. EPER FIM 77-21-00 PIMU BITE SHOWS 352 16A EGT SENSOR AND 352 16B EGT SEN PER PIMU MESS INDEX. REMOVED AND REPLACED SHUNT JUNCTION BOX IAW 77-21-53-4 UP TO OPS CK. SHUNT BOX CKS J131 PIN B TO J3 PIN E OPEN. J131 PIN A TO J4 PIN E OPEN. J131 PIN A & B TO GROUND OPEN ALL OTHER RESIS OK PER FIM PIMU MSG INDEX. COMPLY WITH OPS CHECK GOOD.