What was found
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATT ANGLE FOUND CRACKED JUST AT STA 1575 RBL 75-76 (CRACK 1.5 INCH LENGTH). MAIN DECK FLOOR SUPPORT ATT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATT ANGLE FOUND CRACKED JUST AT STA 1575 RBL 75-76 (CRACK 1.5 INCH LENGTH). MAIN DECK FLOOR SUPPORT ATT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.