As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A MAIN CARGO FLOOR POS 4, CENTER PANEL HAS 2 AREAS THAT HAVE BEEN DAMAGED. REMOVED DAMAGED PER SRM 53-00-50-2 AND EO B767-5320-33101A. INSTALLED CORED & POTTED ALL 3 AREAS PER SAME EO. INSTALLED PLIES ON 1ST & 2ND DAMAGED. INSTALLED REPAIR ON 3RD DAMAGED AND COMPLETED CURE CYCLE. C/W TAP TEST OF REQUIRED AREAS. OK FOR CONTINUED SERVICE. REPAIR COMPLETE PER EO B767-5320-33101A.