What was found
INSPECTION TYPE:7C MCD FLOOR PANEL FOUND CRACK 2 INCH LONG AT STA 975 TO STA 1043 LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:7C MCD FLOOR PANEL FOUND CRACK 2 INCH LONG AT STA 975 TO STA 1043 LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.