As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:7C MAIN DECK BS 246 LBL 27 FLOORBEAM WEB FOUND CRACK. MAIN DECK BS 246 LBL 27 FLOORBEAM WEB REPAIRED AS PER HX RS NO. R53-15-36357 REV A. THIS REPAIR IS CLASSIFIED AS TIME LIMITED UNTIL JUN 25, 2010. PENDING COMPLETION OF THE FATIGUE AND DAMAGE TOLERANCE ANALYSIS. MATERIAL 7075-T6-0032IN USED AS REPAIR DOUBLER, 7075-T6-0.09 & 0.025 USED AS FILLER REPAIR SIZE 7.125 X 13.5 INCHES, B767-5310-34040-A.