What was found
INSPECTION TYPE:7C MAIN EQUIPMENT CENTER STA 246 LBL 40 STIFFENER FOUND CRACK. MAIN EQUIPMENT CENTER STA 246 LBL 40 FLOORBEAM ATTACH STIFFENER REPAIRED AS PER SRM 53-10-51-2R-4, FIG 201, REV 44. THIS REPAIR IS CLASSIFIED AS CATEGORY 'B' MAJOR REPAIR AS PER SRM 53-10-51-2R4, FIG 2 201, REV 44 SHEET 2 TABLE II WITH REPEAT INSPECTION AT 3000 FLIGHT CYCLES OR 24 MONTHS WHICH EVER OCCURS FIRST. MPI P20779 ISSUED.