What was found
INSPECTION TYPE:C AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP FOUND CRACK AT LBL 26, CRACK LENGTH 1 INCH. AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP FOUND CRACK AT LBL 26, CRACK LENGTH 1 INCH. AFT CARGO COMPT STA 1087 FLOOR PNL SUPPORT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 44.