What was found
INSPECTION TYPE:C MAIN EQUIPMENT CENTER STA 246 FLOORBEAM STIFFENER FOUND CRACK AT LBL 40, CRACK LENGTH 1.25 INCH. MAIN EQUIPMENT CTR STA 246 LBL 40 FLOORBEAM STIFFENER REPAIRED PER SRM 53-10-51-2R4 FIG 201 REV 44. THIS CLASSIFIED AS MAJOR REPAIR WITH MATERIAL 7075T6-0063IN AS STIFFENER, 7075T6-0080IN AS DOUBLER, REPAIR LENGTH OF STIFFENER IS 14.5 INCHES (REF UPS MPI P20824 ISSUED FOR REPEAT INSP REQUIRED AS PER SRM 53-10-51-2R4 FIG 201 REV 44 TABLE 2).