What was found
INSPECTION TYPE:C CUSTOMER REQUEST - CARRY OUT PERMANENT REPAIR AT FUSELAGE SKIN DENT AREA AT BS 1418 STR 29L-30L AREA. FASTENERS REMOVED & REINSTALLED WITHIN A 2 INCH PERIPHERY OF THE DENT AREA PER HX RS R53-61-36381 REV A, NO DAMAGES OR CRACK WERE FOUND AFTER DETAIL VISUAL INSP & HFEC INSP PER HX RS R53-61-36381 REV A. THIS REPAIR IS STRUCTURALLY ACCEPTABLE AS CATEGORY B REPAIR WITH REPEAT INSP. (REPEAT INSP DETAIL REF EO B767-5330-34389-A).