As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C MEC COMPT STA 246 FLOORBEAM STIFFENER FOUND CRACK AT LBL 40 ( CRACK LENGTH 1.125" ). MEC COMPT STA 246 FLOORBEAM STIFFENER REPAIRED AS PER SRM 53-10-51- 2R4 FIG 201 AT LBL 40. THIS IS CLASSIFIED A MAJOR REPAIR WITH MATERIAL 7075T6-0063. REPAIR SIZE 15" X 3" THIS IS A CATEGORY 'B' REPAIR MUST BE INSPECTION AS PER SRM 53-10-51-2R4 FIG 201 SHEET 2 TABLE II IPXA MPI P20952 ISSUED FOR THE REPEAT INSP.