What was found
INSPECTION TYPE:C SURVEY SEQ 311-F1-02 FX SKIN REPAIR BETWEEN BS 1836 TO 1850 LBL 7 TO LBL 15 AREA. EXISTING REPAIR DOES NOT CORRELATE TO A SRM. FX SKIN REPAIR BETWEEN BS 1836-1850 LBL 7 TO LBL 15 AREA INCORRECT TYPE OF FASTENERS REPAIRED (REPLACED) PER HX RS R53-80-36422 REV A & EO B767-5330-34892 REV A ACCOMPLISH INITIAL INSP OF REPAIR AREA PER EO APP A WITHIN 30000 CUMULATIVE TOTAL FLT CYC OF ACCOMPLISH EO'S 4A, REPEAT INSP PER EO APP A AT INTERVAL OF 6000 FLT CYC.